400-027-8848Chinese/English
Position:HOME > PRODUCT > High Voltage Insulation Test Equipments

Manual/Auto Controlling Table

                   

 


7.  Manual/Auto Controlling Table


Brief introduction

 

HZXC-101/102series manual/auto controlling table is the manual/auto boost type of power frequency withstand controlling boxes of our company. It with a number of monitoring and protection functions, specially match with light type test transformer and also can be used as ajustable power supply.


Product features

 

◆Monitoring function: output current/high voltage/zero indication/power indication/working indication/timing indication.

◆Protection function:over current protection and zero voltage start-up

◆Using new time relay, timing range is wider.

◆Using new current relay, more accuracy, more reliable, to ensure the safty of personal and equipment.

◆Reasonable structure,small vollume, light weight.

◆Date、voltage、current and time are simutaneously showed as 160 LCD with blue background light, read clear and intuitive.

◆According to the user needs can be equipped with printing function and RS232 mirocomputer communication function. Easy to operate.

◆All Chinese language interface, showing working state and easy to operate, widely applied.

◆The panel is light touching the key operate, all functions can be set through the key, improving the safty and reliability.

◆Digital tuning, Abandoned the old potentiometer adjustment method, easy to use in field.

◆Through key to directly set current and voltage ratio, applicated freely undder different ratio outputing.

◆Can freely achieve AC and DC two type showing throngh single key.

◆Adopted the combinated anti-interference technology of hardware and software, use optimized control mode of stepping motor, Speed fixed-point, stable performance, strong anti-interference ability.

◆Stop condition can be set easily when start uo time relay, setting range: 1-9999second.

◆Setting mode; light touch board the key and digital setup, the setting value keep permanently if power off.

 

Product parameters

 

Specification

HZTC-101/102

Capacity

kVA

Power Supply

Output

HZTC-101/102

Weight

Remark

phase

(V)

(A)

(V)

(A)

10/220

10

1

220

23

0-250

40

Manual/Auto

65

Overall structure

15/380

15

2

380

39

0-430

35

Manual/Auto

70

20/380

20

2

380

53

0-430

50

Manual/Auto

80

25/380

25

2

380

66

0-430

47

Manual/Auto

90

30/380

30

2

380

79

0-430

120

Manual/Auto

100

50/380

50

2

380

132

0-430

116

Electric

Auto/ Electric

160

100/380

100

2

380

263

0-430

232

50

Split structure

150/380

150

2

380

395

0-430

349

50

200/380

200

2

380

526

0-430

465

50

250/380

250

2

380

659

0-430

581

50

300/380

300

2

380

789

0-430

698

50