Variable Frequency Resonant Device

   

 

 

11. Variable Frequency Resonant Device

 

Brief introduction

 

HZBP-BD series variable frequency resonant device is a set of intelligent equipment special for AC withstand test of commen primary electrical equipment of substations. It is applied for the capacity equipments such as transformer, GIS system, SF6 switch, CT\PT, insulator, busbar, cable and bushing ect. This decive is researched and manufactured according to withstand test regulations of 220KV and blow substations primary electrical equipment. It both can santisfy high voltage, small current and low voltage, large current test condition, with wide application range. HZBP using the principle of series resonant, is composed of variable frequency power supply control box(table), driving transformer, reactor and capacity divider.

 

Product features

 

It has smaller vollume and lighter weight compared with the same voltage and capacity reactor. Temperature rises small at the rated load. Dry-type epoxy resin casti with high mechanical strength, good electrical insolating property, nice appearance and reliability.

Variable power supply control box has large capacity margin, strong protection function, good output wave, good stability and various working modes that easy to operate. Single phase 220V and three phase 380V output power are in common use, convenient to take power on site.

Flexible configuration. Can choose to equip with different type reactor to satisfy different tested product. To achieve a multi-purpose machine, cost effective.

 

Product parameter

 

Technique index

Rated Output Voltage

≤0~1000kV

Output Frequency

30~300Hz

Resonate Voltage Waveform

Sine wave, distortion1.0%

Working Mode

Continuous working

Quality Factor

30~90

Frequency Adjustment

0.1Hz

Instability

<0.05%

Power Supply

Single phase 220V or three phase 380V±10%

Power frequency 50Hz±5%

 

Serial product and application

Mode

Application(10kV~500kV transformer substation AC voltage withstand equipment, frequency30~300Hz)

Frequency Power Source

Reactor

Excitation transformer

divider

application

HZBP-BD-50/50/25

3kW

25kV/1A two sets(dry type)

3kVA(dry trpe)

50kV

≤1000kVA 10kV transformer

10kV switch, busbar, PT, CT ect.

10kV(300m) cable1.0km

HZBP-BD-108/108/27

5kW

27kV/1A four sets(dry type)

5kVA(dry type)

110kV

≤31500kVA 35kV transformer

35kV switch, busbar, PT, CT ect.

10kV(300m) cable 2km

35kV(300m) cable 0.5km

HZBP-BD-200/200/50

10kW

50kV/1A four sets(dry type)

10kVA(dry type)

200kV

≤50000kVA 110kV transformer

110KV GIS, PT, CT ect.(preventive test)

35kV(300m) cable ≤1.0km

10kV(300m) cable ≤2.0km

HZBP-BD-270/270/45

15kW

45kV/1A six sets(dry type)

15kVA(dry type)

300kV

≤50000kVA 110kV transformer

110kV GIS, PT, CT ect.

35kV(300m) cable ≤1.2km

10kV(300m) cable ≤3.0km

HZBP-BD-800/400/50

30kW

50kV/2A eight sets(dry type) 100kV/2A four sets(oil immersed)

30kVA(dry type)

30kA(oil immersed)

400kV

≤80000kVA 220kV transformer

≤50000kVA 110kV transformer

110kV/220kV GIS, PT, CT ect.

35kV(300m) cable ≤2.0km

110kV(300m) cable ≤0.7km

HZBP-BD-1600/800/200

60kW

200kV/2A four sets(oil immersed)

60kVA(dry type)

800kV

≤80000kVA 220kV transformer

≤50000kVA 110kV transformer

500kV GIS, PT, CT ect.

220kV switch, busbar, PT, CT ect.

110kV(400m) cable ≤1.5km

220kV(400m) cable ≤1.0km

Note: can customize solution according to the tested product parameters